Dairy Quality and Milk Test Guide

Milk Testing Methods & Labs

How to Take a Proper Milk Sample From the Bulk Tank

A bulk tank sample is a few ounces of milk that gets to speak for thousands of pounds. If it picks up a little sanitizer, a little warm air or a little barn, the lab will report it faithfully and your milk check will believe it. So the job is simple to describe and easy to botch: get a sample that looks like the whole tank, and keep it that way until the lab opens the bottle.

The short version is to agitate the tank long enough, use a clean sample dipper that has been properly sanitized and drained, take the milk from the body of the tank rather than the outlet valve, fill the container without touching the inside of it, label it, and get it cold right away. The rest of this piece covers the reasons, because the reasons are what stop you from improvising your way into a bad number.

Official samples versus your own samples

There are two kinds of bulk tank samples, and mixing them up causes a lot of confusion. Official samples, the ones used for regulatory and milk check testing, are drawn by the hauler or a licensed sampler under the rules of your state and your buyer. You do not pull those, and you should not hand-pick the bottle that goes to the plant.

Your own samples are different. They are the ones you take to check what the hauler's bottle might show, to troubleshoot a rising count, or to send to a lab you chose. They are worth taking precisely because they let you find a problem before the plant report does. The National Mastitis Council notes that bulk tank milk should be sampled so that all cows contributing milk are represented in proportion to what they gave, and that official handling should be done by personnel and protocols certified by the regulatory agency. Their guidelines for sampling and reporting bulk milk cell counts are short and worth a read.

What you need before you walk to the milk house

  • A sample dipper or sampling tool that is clean and sanitized, stored where it stays clean (not in the bucket by the floor drain).
  • Sterile sample vials or the bottles your lab supplied, already labeled.
  • A cooler with ice or frozen packs, set up before you pull the sample, not after.
  • A permanent marker that does not smear when it gets wet. Pencil on a wet bottle is a fine way to produce an anonymous sample.
  • The lab's submission form, filled out as far as you can.

Step by step

  1. Agitate first. Milk separates. Cream rises, and a sample taken from a still tank can read high in fat and low in nearly everything else. Run the agitator for the time your tank manufacturer and your regulator call for (many call for at least 5 minutes, and larger tanks often need 10 or more), and make sure it has been running while the milk covers the paddle or agitator blade. A tank with just one milking in it sometimes does not reach the agitator properly, which is its own sampling problem.
  2. Sanitize and drain your dipper. Sanitizer in a sample is not a harmless little extra. Residue can interfere with bacteria tests and screening tests, and some sanitizers also kill bacteria in the sample and produce a falsely low count, and the lab will have no way to know it was there. Let the dipper drain and air dry, or follow the sanitizing method your milk handler specifies.
  3. Dip from the milk itself. Lower the dipper into the milk away from the wall and the agitator shaft, below the surface foam. Do not take milk from the outlet valve. The valve holds stagnant milk that may not match what is in the tank.
  4. Fill the vial without touching the inside. Keep the cap in your hand, open end down, and do not set it on the lid of the tank. Do not rinse the vial with tank milk, and do not top it off from a second dip if you can avoid it.
  5. Cap, label, chill. Write the farm, the tank, the date, the time and who took it. Put it into ice immediately. A sample that rides around on the dash of the pickup warms up fast, and bacteria do not need an invitation.
  6. Record it. Note the tank temperature and how long the milk had been in the tank when you pulled the sample. If a count comes back strange, these notes are how you work out why.

Where samples go wrong

MistakeWhat it does to the result
Not enough agitationComponent results swing, and cell and bacteria counts may not match what the hauler pulls
Dipper stored dirty or wet with sanitizerFalsely high bacteria counts, or sanitizer residue that interferes with a test
Sample taken at the outlet valveMilk that has been sitting stagnant, not a picture of the whole tank
Warm sample on the way to the labBacteria multiply and the count rises after the sample left the tank
Illegible or missing labelA result nobody can match to a tank, which helps no one

Match the sample to the question

Why you are sampling matters. If you are chasing a rising bacteria count, your sample is only useful if it is clean going in and cold going out, and the cause is more likely to be found by walking the system than by taking ten more samples. Start with where to look first for a high bacteria count, and check that the milk is actually reaching temperature on time, using the bulk tank cooling guide.

If the worry is somatic cells, a bulk tank sample tells you the herd average and nothing about which cow is the problem. For that you need individual cow data, which is where a DHIA report comes in. And once you have a bottle in hand, the next job is keeping it in good shape on the way to the lab, which is covered in handling and shipping samples.

One more rule that belongs here. A private sample is for information. It does not replace the official sample, and it never excuses shipping milk that should not be in the tank. If you are holding milk from treated cows, withdrawal times and discard are for your veterinarian and your milk handler to set, and a clean-looking sample is not a pass.

For the full picture on who takes which sample and how often, see who tests your milk and how often. And for the dairy side of regulation, the National Mastitis Council protocols page collects sampling procedures and related guidelines in one place.

A routine that takes five minutes

Take two vials from the same dip when you troubleshoot, label them A and B, and send both. If the two results differ by more than the lab's stated precision, the problem is sample handling, not the tank. Pick a day and time, say the same hour of the same weekday, and take your own sample after the tank has been agitated and before the hauler arrives. Do it the same way every time. Trends only mean something if the method stays put. If you cannot say why the sample you took last month differs from the one you took this month, the problem is probably the method rather than the milk.

The dipper does not care how many years you have been milking. It cares whether it was clean this morning.

Quick answers

Can I take the sample from the outlet valve?

It is better not to. The valve and the milk sitting in it are not the same as the milk in the tank, so the result may not represent what was shipped. Dip from the tank body after agitation, unless your handler gives you a different instruction.

How cold does the sample need to be?

Cold enough to stop bacteria from multiplying, and kept that way until it reaches the lab. Labs commonly want samples at 32 to 40 F (0 to 4.4 C) on arrival and will not accept ones that arrive warm, so check your lab's cutoff, and ship so the sample arrives within 24 to 48 hours. Put it in ice right after you take it. Your lab will tell you the temperature it expects on arrival and whether a preservative is added.

Why does my sample read different from the hauler's?

Differences in agitation, timing, sample handling and the lab itself all show up. A small gap is normal. A big, repeated gap is a reason to compare methods with your fieldman or the lab and find out which step differs.

More from farm.FM Need a break from the paperwork? Farm humor and funny farm stories are always in season at farm.FM.